USING i.LINK
Status display messages
The following messages may appear on the front panel display depending on the status of this unit.
Error messages
The following messages appear on the front panel display if a connection or registration error is detected.
i.LINK display messages
Message Contents
Link Check Appears while the i.LINK component connection is being checked.
No Name Appears if the model name of the connected i.LINK component cannot be acquired.
No Vendor Name Appears if the vendor name of the connected i.LINK component cannot be acquired.
Message Cause Remedy
Bus Full The 1394 bus transmission band is full, and no
more data can be transmitted.
This problem may be resolved by disconnecting any
unused i.LINK components.
If an i.LINK component with a slow transmission speed
(S100 or S200) is connected between this unit and the
i.LINK (AUDIO) component which you want to play
back, the bus may become full. Changing the
connection order of the i.LINK components so that this
unit and the i.LINK (AUDIO) component are directly
connected may resolve this problem.
Cannot Link The connected i.LINK component is not
recognized because the connection is
incomplete.
Check that all i.LINK components are connected
properly using an IEEE1394 cable.
Loop Connect This unit and the i.LINK component are
connected in a loop (where the output signal is
returned to the original component).
Disconnect the IEEE1394 cable, then reconnect it in
either a daisy chain or tree configuration.
Node Over More than 63 i.LINK components (including
this unit) are connected.
Reduce the number of connected components.
Hop Over More than 15 i.LINK components are
connected in a daisy chain configuration.
Reduce the number of i.LINK components connected
between the two end components to 15 or less.
Reconnect the i.LINK components using the tree-type
connections.