Yamaha 40V Manuel de service Page 216

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 224
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 215
8-29
–+
ELEC
E
CHARGING SYSTEM
CHARGING SYSTEM PEAK VOLTAGE
1. Measure:
Rectifier regulator input
Below specification Lighting coil
measurement.
2. Measure:
Lighting coil output
Beyond specification Replace recti-
fier/regulator.
Below specification Replace light-
ing coil.
FUSE
Refer to “STARTING SYSTEM”.
BATTERY
Refer to “GENERAL” in chapter 3.
Rectifier regurator input:
(electrical model)
8.5 V @ cranking
25 V @ 1,500 r/min
25 V @ 3,500 r/min
Measuring steps:
Connect the tester to the rectifier/regu-
lator as shown.
Set the tester dial to specification.
Range:
Crank or start the engine.
Lighting coil output:
9.0 V @ cranking
25 V @ 1,500 r/min
25 V @ 3,500 r/min
Measuring steps:
Connect the tester to the lighting coil
as shown.
Set the tester dial to specification.
Range:
Start the engine.
V
.......
V
.......
Vue de la page 215

Commentaires sur ces manuels

Pas de commentaire