Vue de la page 54
MIDI Data Format
55
2.2.3 AN1x bulk dump
The AN1x bulk dump messages are received and changed as data of the
PLG150-AN.
11110000 F0H Exclusive status
01000011 43H YAMAHA ID
0000nnnn 0NH N:Device Number
01011100 5CH Model ID
0sssssss SSH ByteCountMSB
0ttttttt TTH ByteCountLSB
0ggggggg GGH Address High
0mmmmmmm MMH Address Mid
0lllllll LLH Address Low
0vvvvvvv VVH Data
: :
0kkkkkkk KKH Check-sum
11110111 F7H End of Exclusive
The details are the same as for 2.2.1 XF Bulk Dump. However, see Table
<3-1> for the Base address.
More details (Address, Byte Count, etc.), see the AN1x parameter list
included with the AN1x.
2.2.3.1 AN1x System bulk dump
When the System block bulk data is received from the AN1x, the PLG150-
AN responds to it.
The following parameters are reacted by the PLG150-AN.
Keyboard Velocity Curve
Keyboard Fixed Veleocity
Keyboard Transmit Channel
Arpeggio/StepSEQ Transmit Channel
Receive Channel 1
Receive Channel 2
Midi Device Number
Midi Local
2.2.3.2 AN1x Current Common bulk dump
When the Common block bulk data of the voice sounds currenly is received
from the AN1x, the PLG150-AN responds to it (see the Table <3-1>).
The following parameters are invalid on the PLG150-AN, or affect differ-
ently compared with the ones applied to the AN1x.
Scene Select (Always "Scene1" is fixed.)
Layer Mode ("Single" or "Unison")
Layer Pan, Layer Separation
Common Vtrl Matrix 1—2 Data (Source, Parameter, Depth)
Vari-Ef Type (Always "Gutar Amp.Simulator" is fixed.)
Dly-Ef, Rev-Ef Data (Type, Return, Parameter 1—7)
Arpeggio/StepSEQ Scene Sw. ("Off" or "On (only Scene1-side)")
FreeEG Track Scene Switch ("Off or "On (only Scene1-side)")
2.2.3.3 AN1x Current Scene1 bulk dump
When the Scene1 block bulk data of the voice sounds currenly is received
from the AN1x, the PLG150-AN responds to it (see the Table <3-1>).
The following parameters are reacted by the PLG150-AN.
Ctrl Matrix 16 Data (Source, Parameter, Depth)
2.2.3.4 AN1x Current Step Seq Pattern bulk dump
When the Step SEQ block of the voice sounds currenly is received from the
AN1x, the PLG150-AN responds to it (see the Table <3-1>).
2.2.3.5 AN1x User Pattern bulk dump
When the User Step Seq Pattern block bulk data is received from the AN1x,
the PLG150-AN responds to it (see the Table <3-1>).
2.2.3.6 AN1x User Voice bulk dump
When the User Voice block bulk data is received from the AN1x, the
PLG150-AN responds to it (see the Table <3-1>).
The following parameters are invalid on the PLG150-AN, or affect differ-
ently compared with the ones applied to the AN1x.
Data of Scene 2
Common Data (See 2.2.3.2)
Scene1 Data (See 2.2.3.3)
3. Realtime Messages
3.1 Active Sensing
a) Send
This is not transmitted.
b) Receive
After FE is received one time, if the MIDI signal does not come within 400
msec, PLG150-AN will act the same as when ALL SOUND OFF, ALL
NOTE OFF, and RESET ALL CONTROLLERS are received, and return
to the condition where has not been received once.
<1-1>
Parameter Base Address
MODEL ID = 4C
<1-2>
MIDI Parameter Change table ( XG SYSTEM )
Address Size Data Parameter Description Default
(H) (H) (H) (H)
0 0 0 4 00 - 0F MASTER TUNE -102.4...0...+102.3[cent] 00 04 00 00
1 00 - 0F 1st bit3-0mbit15-12
2 00 - 0F 2nd bit3-0mbit11-8
3 00 - 0F 3rd bit3-0mbit7-4
4th bit3-0mbit3-0
4 1 00 - 7F MASTER VOLUME** 0...127 7F
5 1 00 - 7F MASTER ATTENUATOR** 0...127 0
6 1 28 - 58 TRANSPOSE -24...0...+24[semitones] 40
7D 1 NOT USED
7E 1 0 XG SYSTEM ON 00=XG system ON (receive only)
7F 1 0 ALL PARAMETER RESET 00=ON (receive only)
TOTAL SIZE 7
** Processed on the XG platform side (MU128, MU100, etc.)
Parameter Address Description
(H) (M) (L)
XG SYSTEM 00 00 00 System
00 00 7E XG System On
00 00 7F All Parameter Reset
MULTI PART 08 00 00
: : :
08 0F 00
Multi Part 1
:
Multi Part 16
MULTI PART
(additional)
0A 00 00
: : :
0A 0F 00
Multi Part 1
:
Multi Part 16
PART ASSIGN 70 03 nn PLG150-AN Part Assign
( nn = PLG150-AN serial number )