Yamaha YSP-600 Manuel de service Page 44

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 99
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 43
44
YSP-600/HTY-760
YSP-600/HTY-760
K0/K1 (Panel key of this unit)
A/D of the key fails to function properly when the standard
value is deviated by ±2%. In this case, check the constant
of voltage dividing resistor, solder condition, etc.
(Reference voltage: 3.3V=100%)
K0/K1 (本機パネルキー)




[%]
0+2
10±2
100-2
K0
VOLUME +
INPUT
NO KEY
K1
VOLUME -
NO KEY
K0:100 K1:099
9. AD DATA CHECK
This menu is used to display the A/D conversion value
of the main microprocessor which detects panel keys
of this unit and protection functions in % using the sub-
menu. During signal processing, the condition before
execution is maintained.
PS (Power supply voltage protection detection)
* When the value of PS, P2 and P3 is not at the normal
value level, the protection function works and the power
is turned off.
(Reference voltage: 3.3V=100%)
PS (PS1) Voltage detects: -24V, +5V, +6.3V
Normal value: 48.7 to 91.3 %
(1.6 to 3.0 V)
P2 (PS2) Voltage detects: +12V, +10V, D+12
Normal value: 63.9 to 88.2 %
(2.1 to 2.9 V)
P3 (PS3) Voltage detects: +3.3 V
Normal value: 66.9 to 85.2 %
(2.2 to 2.8 V)
* The normal value has been revised from 2.5V
(measured value) to 3.3V (indicated value) by the
voltage dividing resistor.
9. AD DATA CHECK



PS (電源電圧プロテクションの検出)



PS(PS1) 
 
P2(PS2) 
 
P3(PS3) 
 
 

PS:068%[2.24V]
P2:077%[2.54V]
P3:077%[2.54V]
Vue de la page 43