Yamaha RX-V620RDS Manuel d'utilisateur Page 61

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 82
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 60
59
English
INTRODUCTION
PREPARATION
BASIC OPERA-
TION
ADVANCED
OPERATION
ADDITIONAL
INFORMATION
APPENDIX
SOUND FIELD PROGRAM PARAMETER EDITINGSOUND FIELD PROGRAM PARAMETER EDITING
Changing Parameter Settings
Although it is possible to enjoy playback on your system
without changing default setting parameters for the sound
field program, it is also possible to enjoy specifically
tailor the sound field program to the characteristics of the
source and the acoustics of the listening room.
1 Set the selector dial to the DSP/TUN (or
AMP/TUN) position.
or
2 Turn on the video monitor
and press ON SCREEN
repeatedly to select the
full display mode.
3 Select a DSP program you want to adjust.
A/B/C/D/E
A/B/C/D/E
2
5
4
1
3
3
Program No. Program name (group)
Cursor
Parameters
Example of the MOVIE THEATER 1
4 Press u/d to select the
parameter.
5 Press j / i to change the
parameter value.
y
When you set the parameter to a value other than the factory-
set value, an asterisk mark (*) appears by the parameter name
on the video monitor.
6 Repeat steps 3 to 5 above as necessary to
change other program parameters.
Memory back-up
The memory back-up circuit prevents the stored data
from being lost even if this unit is set in the standby
mode, the power cord is disconnected from the AC
outlet, or the power supply is temporarily cut due to
power failure. However, if the power is cut for more
than one week, the parameter value you edited will
return to the factory setting. If so, edit the parameter
value again.
Resetting a Parameter to the
Factory-set Value
Select the parameter you want to reset. Then press and
hold j or i until the value temporarily stops at the
factory-set value. The asterisk mark (*) by the parameter
name disappears on the video monitor.
Notes
The available parameters may be displayed on more than one
OSD page for some of the programs. To scroll through pages,
press u/d.
You cannot change parameter values when 10 MEMORY
GUARD on the SET MENU is set to ON. If you want to
change the parameter values, set 10 MEMORY GUARD to
OFF.
P07 MOVIE THEATER 1
P. INIT. DLY 13ms
70mm Spectacle
S. DELAY
23ms
P. ROOM SIZE 1.0
S. ROOM SIZE 1.0
0111V620RDS_58-62_EN 1/18/1, 7:27 PM59
Vue de la page 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 81 82

Commentaires sur ces manuels

Pas de commentaire