M7CL Quick Start Guide Part 1
5
Scene 000 or Initialization?
Before working on an analogue console it is customary to check that the console has been “set to zero”. This
normally means setting the gain to minimum, the EQ to at, auxes to at, group routing de-selected, insert points
switched off, etc. Look at and check upwards of 1000 knobs! Because M7CL can memorise its settings, Yamaha have
provided a handy memorised scene (Scene000) where the console is set to zero ready to start at the touch of a
button.
Scene 000
To recall Scene 000 press the up/down keys until SCENE
000 ashes in the [Scene Panel]. Then press [RECALL]
Preparing the console before you start.
However certain features of M7CL are not under scene control. For example word clock settings, Outport settings
and User De ned Keys are not recalled by scene control. Also, as we will explore in later parts of the User Guide
various things normally controlled by scenes can be actively removed from scene control. This can mean that
recalling Scene 000 does not “set to zero” as expected. Returning the whole console to factory default setting is
called “Initialization” and this is recommended when starting a completely new project.
Note;
Note; Initialization removes all user settings from the console and so should only be done if any valuable
user data on the console is backed up. (To a USB memory key or Studio Manager/M7CL Editor le on a PC).
Tip;
Tip; Users, particularly in xed installs, may wish to create their own “Session Starting Point” saved to a
USB key rather than using the factory default. This “Session Starting Point” could include correct port delays
and output patching.
Not included in Scene recall. (So not reset by Scene 000)
but still remembered for all scenes.
User de ned keys
Preferences
Brightness controls
OUTPORT delay and level settings
MIDI setup
Wordclock
Master +48V
CUE Pop-up; PFL trim ins, DCA trim, PFL trim Outs
Monitor Pop-up; (levels, source on/off, mono, link)
Oscillator (all parameters)
Safe assignments (mute, recall)
Passwords/Admin/guest settings
Screen page or pop-up
Sends on fader selected
Metering point selection
External HA to Slot assignment and HPF.
User Access Level
Network settings
Clock!!
Slots and MY Card settings
User Libraries
EQ/HPF, (User and ROM)
Dynamics (not key-in), (User and ROM)
GEQ, (User only)
Effects (User and ROM)
Check your console rmware version.
This guide relates to M7CL Version 3 console rmware. If you
have older rmware we recommend an upgrade to version 3. The
rmware can be freely downloaded from www.yamahaproaudio.
com>>Downloads.
V3.xx